Laserfiche WebLink
<br />Measureme nt of Energy and Determination of Demand <br />- Energy supplied hereunder will be delivered through not more than 1 single phase <br />and/or 1 polyphase meter. Billing demand in kva shall be taken each month as the highest <br />15-minute integrated peak in kilowatts as registered during the month by a l5-minute <br />,""'_ integrating demand meter or indicator, or at the canpany's option as the highest regist- <br />ration of a thermal type demand meter or indicator, divided by the average monthly power <br />factor established during the month, corrected to the nearest kva. Where energy is <br />delivered through 2 meters, the billing demand will be taken as the sum of the 2 demands <br />separately determined. Monthly billing demand established hereunder shall not be less <br />than the customer IS contract capacity except that where the customer purchases his entire <br />requirements for electric light, heat and povTer under this tariff, the monthly billing <br />demand shall not be less than 6afo of the customer's contract capacity. In no event shall <br />the monthly billing demand be less than 50 kva. <br /> <br />.",,--,,, <br /> <br />Credits and Charges Modifying Rate <br />Bills computed under the rate set forth herein will be modified by debits or credits <br />as follows: <br />(A) Power Fac tor <br />The rate set forth in this tariff is based upon the maintenance by the customer <br />of an average power factor of 85% for each month, as shown by integrating instruments. <br />When the average monthly power factor is above or below 85% the kwhrs. as metered <br />will for billing purposes be multiplied by the following constants: <br /> <br />... <br />CD <br />.,. <br />.,. <br /> <br />~ <br />~ <br /> <br />z: <br /> <br />Effective Monthly Power Factor <br />1.00 <br />.95 <br />.90 <br />.85 <br />.80 <br />.75 <br />.70 <br />.65 <br />.60 <br />.55 <br />.50 <br /> <br />Constant <br />.951 <br />.965 <br />.981 <br />1.000 <br />1.023 <br />1.050 <br />1.0835 <br />1.1255 <br />1.1785 <br />1.2455 <br />1.3335 <br /> <br />~ <br /> <br />o <br />1 <br />"0 <br /> <br />;; m!i~ <br />j 1t,i <br />;-: <br /> <br />.~ <br /> <br />:) <br />:; <br />U <br /> <br />Constants for other than the effective power factors given in the foregoing <br />table will be determined from the same formula used to determine the given constants. <br /> <br />- <br /> <br />(B) Delivery Voltage <br />The rate set forth in this tariff is based upon the delivery and measurement <br />of transformed energy, When the measurement of energy is made at the primary <br />voltage of the transmission or distribution line used to supply the customer the <br />energy as billed after power factor correction (see Paragraph A) will be Imlltiplied <br />by .95. <br /> <br />(c) Equipment Supplied by Customer <br />When the customer furnishes and maintains the complete substation equipment <br />including any and all transformers, switches and other apparatus necessary for the <br />customer to take service at the voltage of the primary transmission or distribution <br />line from which said customer is to receive service, the following credits in <br />addition to that set forth in the next preceding paragraph will be applied to each <br />monthly net bill. <br /> <br />-2 <br /> <br />- <br />